[Previous][Next]
REMOVAL AND INSTALLATION
 
 
caution
  • When removing or installing the volume air flow sensor, be careful not to apply impact to the sensor.
  • Do not reuse the volume air flow sensor that has been dropped.
Removal steps
1.Air cleaner intake duct
2.Breather hose
3.Air cleaner air intake hose
>>A<<4.Volume volume air flow sensor
5.O-ring
6.Air cleaner cover
7.Air cleaner element
8.Air cleaner body
Engine control module (Refer to GROUP 13A - Engine control module )
9.Air cleaner bracket
 
 
INSTALLATION SERVICE POINT
 
 
>>A<< AIR CLEANER VOLUME AIR FLOW SENSOR INSTALLATION
1. Install the volume air flow sensor to the air cleaner cover with care not to damage the O-ring.
2.
cautionDo not over-tighten. If the mounting screw is over-tightened, the air cleaner cover can be damaged.
Tighten the mounting screws to the specified torque.
Tightening torque: 1.5 ± 0.3 N·m (13 ± 2 in-lb)