INITIALIZATION PROCEDURE
Required Special Tools:
- MB992744: Vehicle Communication Interface-Lite (V.C.I.-Lite)
- MB992745: V.C.I.-Lite Main Harness A
- MB992747: V.C.I.-Lite USB Cable Short
- MB992748: V.C.I.-Lite USB Cable Long
caution | To prevent damage to the scan tool (M.U.T.-IIISE), always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting the scan tool (M.U.T.-IIISE). |
1. After the ignition switch is in "LOCK" (OFF) position, connect scan tool (M.U.T.-IIISE) to the data link connector.
2. Turn the ignition switch to the "ON" position.
3. Select "MFI" from System select Screen of the scan tool (M.U.T.-IIISE).
4. Select "Special Function" form MFI Screen.
5. Select "Timing chain maintenance" from Special Function Screen.
6. Select "Learned value reset" form Timing chain maintenance Screen.
7. Press "ON" to reset the learning value.