|
1.Park the vehicle on a level surface.
|
|
2.
caution |
Before connecting or disconnecting the scan tool, turn the ignition switch to the "LOCK" (OFF) position.
|
Set the scan tool with the ignition "LOCK" (OFF).
|
|
3.Turn the ignition switch to the ON position.
|
|
4.Select the relevant system from the menu.
|
|
5.Select "ABS/ASC/ASTC/WSS" from the system lists in "System select", and press "OK" button.
|
|
6.Select "Special function" in "ABS/ASC/ASTC/WSS".
|
|
7.Select "Sensor calibration" in "Special function".
|
|
8.Select "G sensor calibration" from the selected item, and press "OK" button.
|
|
9.The screen displays "G sensor calibration: The selected command will be executed. Are you sure? Caution: Please check the execution conditions." Then press "OK" button.
|
|
10."Execute: The command was executed." will be shown. Then press "OK" button.
|
|
11.Select "Lateral G sensor calibration" from the selected item, and press "OK" button.
|
|
12.The screen displays "Lateral G sensor calibration: The selected command will be executed. Are you sure? Caution: Please check execution conditions." Then press "OK" button.
|
|
13."Executed: The command was executed." will be shown. Then press "OK" button.
|
|
14.Learning neutral point complete
|
|
15.Turn the ignition switch to "LOCK" (OFF) position and then disconnect the scan tool.
|
|
1.Carry out steps 1 to 13 of the G and yaw rate sensor calibration for vehicles without TC-SST.
|
|
2.Select the relevant system from the menu.
|
|
3.Select "ACD/AYC" from the system lists in "System select", and press "OK" button.
|
|
4.Select "Special function" in "ACD/AYC".
|
|
5.Select "Sensor calibration" in "Special function".
|
|
6.Select "Lateral G sensor calibration" from the selected item, and press "OK" button.
|
|
7.The screen displays "Lateral G sensor calibration: The selected command will be executed. Are you sure? Caution: Please check the execution conditions." Then press "OK" button.
|
|
8."Execute: The command was executed." will be shown. Then press "OK" button.
|
|
9.Select "Longitudinal G SNS.calibration" from the selected item, and press "OK" button.
|
|
10.The screen displays "Longitudinal G SNS.calibration: The selected command will be executed. Are you sure? Caution: Please check execution conditions." Then press "OK" button.
|
|
11."Executed: The command was executed." will be shown. Then press "OK" button.
|
|
12.Learning neutral point complete
|
|
13.Turn the ignition switch to "LOCK" (OFF) position and then disconnect the scan tool.
|