[Previous] [Next]

DTC P1740: Malfunction of Lockup/Select Switching Solenoid Valve




SOLENOID VALVE SYSTEM CIRCUIT


Refer to .

DIAGNOSTIC FUNCTION


TCM detects abnormal operation of the lockup/select switching solenoid valve.

DESCRIPTIONS OF MONITOR METHODS




MONITOR EXECUTION




MONITOR EXECUTION CONDITIONS (OTHER MONITOR AND SENSOR)


Other Monitor (There is no temporary DTC stored in memory for the item monitored below)
Sensor (The sensor below is determined to be normal)

LOGIC FLOW CHARTS (Monitor Sequence)





DTC SET CONDITIONS


Judgment Criteria

OBD-II DRIVE CYCLE PATTERN


Ignition switch : ON (start the engine and keep it for 10 seconds or more)

PROBABLE CAUSES




PROBABLE CAUSES




DIAGNOSTIC PROCEDURE


STEP 1. M.U.T.-III data list



    Item 36: LU/SEL changeover SOL. output
    Item 37: LU/SEL changeover SOL. monitor
OK: Check that the output and monitor do not differ greatly.

Q. Is the check result normal?

Intermittent malfunction
Go to Step 2.

STEP 2. Check the following connector:



  • B-08 CVT assembly connector
  • C-41 TCM connector
  • A-09 Intermediate connector
Check the terminals for a contact status problem and internal short circuit.

Q. Is the check result normal?

Go to Step 3.
Repair the defective connector.

STEP 3. Check for open circuit and short to ground in the wiring harness between the TCM connector and the CVT assembly connector.


Between C-41 TCM connector (terminal No.14) and B-08 CVT assembly connector (terminal No.4)

Q. Is the check result normal?

Go to Step 4.
Repair the wiring harness.

STEP 4. Lockup/select switching solenoid valve single unit check


Refer to .

Q. Is the check result normal?

Go to Step 5.
Replace the valve body assembly.

STEP 5. Symptom recheck after erasing diagnosis code


Q. Is the check result normal?

Intermittent malfunction
Replace TCM.