- Item 4: Secondary pressure sensor signal (Refer to Data List Reference Table .)
|
|
Q.
Is the check result normal?
|
|
- B-08 CVT assembly connector
- C-40 TCM connector
- A-09 Intermediate connector
|
|
Check the terminals for a contact status problem and internal short circuit.
|
|
Q.
Is the check result normal?
|
|
Repair the defective connector.
|
|
|
|
- Between C-40 TCM connector (terminal No.39) and B-08 CVT assembly connector (terminal No.7)
- Between C-40 TCM connector (terminal No.48) and B-08 CVT assembly connector (terminal No.19)
- Between C-40 TCM connector (terminal No.49) and B-08 CVT assembly connector (terminal No.5)
|
|
Q.
Is the check result normal?
|
|
Repair the wiring harness.
|
|
|
|
Q.
Is the check result normal?
|
|
The procedure is complete.
|
|
|