[Previous] [Next]

DTC P0234: Turbocharger Wastegate System Malfunction




TECHNICAL DESCRIPTION




DESCRIPTIONS OF MONITOR METHODS


It detects overcharging failure by monitoring intake air volume.

MONITOR EXECUTION


Continuous

MONITOR EXECUTION CONDITIONS (Other monitor and Sensor)


Other Monitor (There is no temporary DTC stored in memory for the item monitored below)
Sensor (The sensor below is determined to be normal)

DTC SET CONDITIONS


Logic Flow Chart


Check Condition, Judgement Criterion

FAIL-SAFE AND BACKUP FUNCTION




OBD-II DRIVE CYCLE PATTERN


Refer to Diagnostic Function - OBD-II Drive Cycle - Pattern 17.

TROUBLESHOOTING HINTS (The most likely causes for this code to be set are:)




DIAGNOSIS


STEP 1. Check the intake charge pressure.


Refer to GROUP 15, On-vehicle Service - Intake Charge Pressure Check .

Q. Are there any abnormalities?

Repair it. Then go to Step 4.
Go to Step 2.

STEP 2. Check the intake charge pressure control system.


Refer to GROUP 15, On-vehicle Service - Intake Charge Pressure Control System Check .

Q. Are there any abnormalities?

Repair it. Then go to Step 4.
Go to Step 3.

STEP 3. Check the turbocharger wastegate actuator.


Refer to GROUP 15, On-vehicle Service - Turbocharger Wastegate Actuator Check .

Q. Are there any abnormalities?

Repair or replace it. Then go to Step 4.
Go to Step 4.

STEP 4. Test the OBD-II drive cycle.


(1)Carry out test drive with the drive cycle pattern. Refer to Diagnostic Function - OBD-II Drive Cycle - Pattern 17 .
(2)Check the diagnostic trouble code (DTC).

Q. Is the DTC P0234 set?

Retry the troubleshooting.
The inspection is complete.