STEP 1. Resistance measurement at the column switch connector
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Measure the resistance between the column switch connector (GND terminal) and the ground.OK: The resistance should be 2 ohms or less
Is the check result normal?
Go to Step 3. Go to Step 2.
STEP 2. Check of open circuit in GND line between column switch connector and ground
STEP 3. Voltage measurement at the column switch connector.
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Measure the voltage between the column switch connector (+B terminal) and the ground.OK: The voltage should measure approximately 12 volts (battery positive voltage).
Is the check result normal?
Go to Step 5. Go to Step 4.
STEP 4. Check of short to power supply, and open circuit in +B line between column switch connector and junction block connector.
STEP 5. Check of open circuit in LIN line between ETACS-ECU connector and column switch connector.
STEP 6. Recheck for diagnostic trouble code.
Check again if the DTC is set in the ETACS-ECU.(1) caution | To prevent damage to scan tool (M.U.T.-III), always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool (M.U.T.-III). |
Connect scan tool (M.U.T.-III). Refer to "How to connect the Scan Tool (M.U.T.-III)
."
(2) Erase the DTC.
(3) Turn the ignition switch from "LOCK" (OFF) position to "ON" position.
(4) Check if DTC is set.
Is the DTC set?
Replace the column switch. A poor connection, open circuit, or other intermittent malfunctions in the LIN bus lines between the column switch and the ETACS-ECU (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).