| caution | To prevent damage to scan tool (M.U.T.-III), always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool (M.U.T.-III). | 
| note | When the special tool MB992745 is connected to the data link connector, the special tool MB992744 indicator light will be illuminated in a green color. | 
| note | When special tool MB991824 is energized, special tool MB991824 indicator light will be illuminated in a green color. | 
| note | Disconnecting scan tool (M.U.T.-III) is the reverse of the connecting sequence, making sure that the ignition switch is at the "LOCK" (OFF) position. | 
| note | If the battery voltage is low, diagnostic trouble codes will not be set. Check the battery if scan tool (M.U.T.-III) does not display. | 
| note | When the "Loading Option Setup" list is displayed, check the applicable item. | 
| Item No. | Item name | Data item | Unit | 
| 1 | Odometer | Total driving distance after the diagnostic trouble code is generated | mile <except vehicles for Canada> km (or mile) <vehicles for Canada>  | 
| 2 | Ignition cycle | Number of times the ignition switch is turned "ON" position or "LOCK" (OFF) position after the past failure transition | Number of counts is displayed. | 
| 4 | Accumulated minute | Cumulative time for current malfunction of diagnostic trouble code | min |