caution | To prevent damage to scan tool (M.U.T.-III), always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool (M.U.T.-III). |
note | when the special tool MB992745 is connected to the data link connector, the special tool MB992744 indicator light will be illuminated in a green color |
note | When special tool MB991824 is energized, special tool MB991824 indicator light will be illuminated in a green color. |
note | Disconnecting scan tool (M.U.T.-III) is the reverse of the connecting sequence, making sure that the ignition switch is at the "LOCK" (OFF) position. |
caution | To prevent damage to scan tool (M.U.T.-III), always turn the power supply mode of the engine switch to the OFF position before connecting or disconnecting scan tool (M.U.T.-III). |
note | If the battery voltage is low, diagnostic trouble codes will not be set. Check the battery if scan tool (M.U.T.-III) does not display. |
note | When the "Loading Option Setup" list is displayed, check the applicable item. |
Item No. | Item name | Data item | Unit |
01 | Odometer | Total driving distance after the diagnostic trouble code is generated | mile<except vehicles for Canada> km (or mile)<vehicles for Canada> |
02 | Ignition cycle | Number of times the ignition switch is turned "ON" or "LOCK (OFF)" after the past failure transition | Number of counts is displayed. |
04 | Current trouble accumulative time | Cumulative time for current malfunction of diagnostic trouble code | min |