STEP 1. Checking central door locking system operation.
STEP 2. Central door lock switch check (built in the power window main switch).
STEP 3. Check of short to power supply, short to ground, and open circuit in D-LS+A-LS, D-US+A-US line between ETACS-ECU connector and power window main switch connector.
STEP 4. Check of open circuit in ground line between power window main switch connector and the ground.
STEP 5. Retest the system.
Check that the central door locking system works normally.Is the check result normal?
No action is necessary and testing is complete. Replace ETACS-ECU.