STEP 1. Confirmation of the defective door lock actuator or liftgate lock actuator.
STEP 2. Front door lock actuator (LH) check
STEP 3. Check of short to power supply, short to ground, and open circuit in RR-L, RL-U line between the ETACS-ECU connector and front door lock actuator (LH) connector
STEP 4. Front door lock actuator (RH) check
STEP 5. Check of short to power supply, short to ground, and open circuit in RR-L, RL-U line between the ETACS-ECU connector and the front door lock actuator (RH) connector
STEP 6. Rear door lock actuator (LH) check
STEP 7. Check of short to power supply, short to ground, and open circuit in RR-L, RL-U line between the ETACS-ECU connector and the rear door lock actuator (LH) connector
STEP 8. Rear door lock actuator (RH) check
STEP 9. Check of short to power supply, short to ground, and open circuit in RR-L, RL-U line between the ETACS-ECU connector and the rear door lock actuator (RH) connector