STEP 6. Measure the output wave pattern of the primary pulley speed sensor at TCM connector (PRMS terminal).
(1) Connect the primary pulley speed sensor connector and TCM connector.
(2) Transmission range: "L" range.
(3) Drive at a constant speed of approximately 20 km/h (12.4 mph).
(4) Connect an oscilloscope, and measure the voltage between TCM connector PRMS terminal and body ground.OK: A wave pattern such as the one shown on (Check Procedure Using an Oscilloscope) should be output, and the maximum value should be 11 V or more and the minimum value should be 1 V or less. There should be no noise in the output wave pattern. Is the check result normal?
Go to Step 7. Replace the primary pulley speed sensor.