<Checking the Coil Resistance>
1. Disconnect the oil feeder control valve connector.
2. Measure the resistance between terminals.Standard value: 6.9 - 7.9 Ω [at 20°C (68°F)]
3. If the resistance is not within the standard value, replace the oil feeder control valve.