[Previous][Next]
Diagnostic Item 5: Diagnose when the scan tool cannot receive the data sent by ETACS-ECU.
 
 
cautionWhen servicing a CAN bus line, ground yourself by touching a metal object such as an unpainted water pipe. If you fail to do, a component connected to the CAN bus line may be broken.
 
 
FUNCTION
The diagnostic result demonstrates that "the scan tool (M.U.T.-III) cannot receive the sent data from the ETACS-ECU" when the scan tool (M.U.T.-III) checks the periodically sent data from each ECU and cannot receive the ETACS-ECU data only.
 
 
TROUBLE JUDGMENT CONDITIONS
Scan tool (M.U.T.-III) judges the trouble when the periodically sent data from ETACS-ECU cannot be received.
 
 
PROBABLE CAUSES
  • Damaged harness wires and connectors
  • Power supply circuit malfunction of the ETACS-ECU
  • Malfunction of the ETACS-ECU
 
 
DIAGNOSIS
STEP 1. Connector check: joint connector (CAN1) and ETACS-ECU connector
cautionThe strand end of the twist wire should be within 10 cm from the connector. For details refer to .
When checking the joint connector, ensure that its wiring harness side and its short pins are not damaged.
Is the check result normal?
Go to Step 2.
Repair the defective connector. Replace the joint connector as necessary.
 
STEP 2. Resistance measurement at joint connector (CAN1) and ETACS-ECU connector.
cautionA digital multimeter should be used. For details refer to .
cautionThe test wiring harness should be used. For details refer to .
(1) Disconnect the joint connector (CAN1) and the ETACS-ECU connector, and measure at the wiring harness side.
(2) Turn the ignition switch to the LOCK (OFF) position.
(3)
cautionWhen measuring the resistance, disconnect the negative battery terminal. For details refer to .
Ensure that the negative battery terminal is disconnected.
(4) Continuity between joint connector (CAN1) terminal No.10 and ETACS-ECU connector terminal No.56
OK: Continuity (2 Ω or less)
(5) Continuity between joint connector (CAN1) terminal No.21 and ETACS-ECU connector terminal No.65
OK: Continuity (2 Ω or less)
cautionStrictly observe the specified wiring harness repair procedure. For details refer to .
Is the check result normal?
<All the resistances measure 2 Ω or less> Go to Step 3.
<Either or all of the resistances measure more than 2 Ω> Repair the wiring harness between joint connector (CAN1) and the ETACS-ECU connector.
 
STEP 3. Resistance measurement at ETACS-ECU connector.
cautionA digital multimeter should be used. For details refer to .
(1) Remove the ETACS-ECU, and measure at the equipment side.
(2) Resistance at ETACS-ECU connector terminal Nos.56 and 65
OK: 120 ± 20 Ω
Is the check result normal?
<Within 120 ± 20 Ω> Power supply to the ETACS-ECU may be suspected. Refer to .
<Not within 120 ± 20 Ω> Replace the ETACS-ECU.