STEP 1. Check the CAN bus lines for short to power supply. Voltage measurement at data link connector.
caution | A digital multimeter should be used. For details refer to . |
caution | The test wiring harness should be used. For details refer to . |
(1) Connect the negative battery terminal, and turn the ignition switch to the ON position.
(2) Voltage between data link connector terminal No.6 (CAN_H) and body groundOK: Less than 4.0 V
(3) Voltage between data link connector terminal No.14 (CAN_L) and body groundOK: Less than 4.0 V
(4) Disconnect the negative battery terminal.
Is the check result normal?
<Voltage is less than 4.0 V in both CAN_H and CAN_L> :
Go to Step 2. <Voltage is 4.0 V or more in either CAN_H or CAN_L> :
Perform diagnosis item 2 "Diagnose shorts in the power supply to CAN bus line". Refer to .