Inspection Procedure 4: The front door lock actuator (driver’s side) signal is not received.
 
 
cautionWhenever the ECU is replaced, ensure that the power supply circuit, the ground circuit and the communication circuit are normal.
 
 
TECHNICAL DESCRIPTION (COMMENT)
The front door lock actuator (driver’s side) input signal is used for the operation judgment of the functions below. If the signal is abnormal, these functions will not work normally.
  • Central door locking
  • Keyless entry system
  • Dome light
 
 
TROUBLESHOOTING HINTS
  • The front door lock actuator (driver’s side) may be defective
  • The ETACS-ECU may be defective
  • The wiring harness or connectors may have loose, corroded, or damaged terminals, or terminals pushed back in the connector
 
 
DIAGNOSIS
Required Special Tools:
  • MB991223: Harness Set
  • MB992006: Extra Fine Probe
STEP 1. Front door lock actuator (driver’s side) check
Refer to GROUP 42A - Door .
Is the check result normal?
Go to Step 2.
Replace the front door lock actuator (driver’s side).
 
STEP 2. Resistance measurement at front door lock actuator (RH) connector (ground terminal)
(1) Disconnect the connector, and measure at the wiring harness side.
(2) Measure the resistance between the door lock actuator (RH) connector (ground terminal) and ground.
OK: The resistance should be 2 ohms or less
Is the check result normal?
Go to Step 4.
Go to Step 3.
 
STEP 3. Check of open circuit in ground line between front door lock actuator (RH) connector and ground
Is the check result normal?
Intermittent malfunction is suspected (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).
Repair the connector(s) or wiring harness.
 
STEP 4. Check of short to power supply, short to ground, and open circuit in DSWL, DSWU line between ETACS-ECU connector and front door lock actuator (RH) connector
Is the check result normal?
Go to Step 5.
Repair the connector(s) or wiring harness.
 
STEP 5. Using scan tool (M.U.T.-III), check data list.
(1)
cautionTo prevent damage to scan tool (M.U.T.-III), always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool (M.U.T.-III).
Connect scan tool (M.U.T.-III). Refer to "How to connect Scan Tool (M.U.T.-III) ."
(2) Change the status of driver's door from unlocked to locked.
 
Item No.Item nameNormal condition
20Driver's door unlock switchON → OFF
21Driver's door lock switchOFF → ON
OK: Normal condition is displayed.
Is the check result normal?
The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).
Replace the ETACS-ECU.