[Previous][Next]
FUEL LEVEL SENSOR CHECK
 
 

 
 
NOMINAL RESISTANCE OF THE FUEL LEVEL SENSOR
1. Remove the fuel pump module (Refer to GROUP 13B - On-Vehicle Service ).
2. When float of the fuel level sensor is in stopper positions F and E, ensure that resistance between the fuel level sensor terminal and ground terminal is within the standard value.
Standard value:
 
Float positionGauge resistance value (ohms)
Stopper position "F"13.0 ± 1.0
Stopper position "E"120.0 ± 1.0
3. When the float is moved slowly between stopper positions "F" and "E", ensure that the resistance is smoothly changing.
 

 
 
FUEL LEVEL SENSOR FLOAT HEIGHT
1. Remove the fuel pump module (Refer to GROUP 13B - On-Vehicle Service ).
2. When float is moved to contact the float arm on the stopper, ensure that stopper positions "F" (height A) and "E" (height B) are within the standard value.
Standard value:
 
Float positionFloat height {mm (in)}
Stopper position "F" (height A)135.4 ± 5.0 (5.3 ± 0.2)
Stopper position "E" (height B)14.9 ± 5.0 (0.6 ± 0.2)