[Previous][Next]
STOPLIGHT SWITCH CHECK
 
 
 
 
<M/T>
cautionDo not apply grease or lubricant to the switch and the switch installation section to avoid malfunction of the switch. In addition, do not use gloves which have grease on them.
Check for continuity between the terminals of the switch.
 
Check conditionTerminal connector of testerNormal condition
At free position1 - 2Continuity exists
(2 Ω or less)
Press the plunger from the edge of the outer case by the dimension shown in the figure.1 - 2No continuity
 
 
 
<CVT>
cautionDo not apply grease or lubricant to the switch and the switch installation section to avoid malfunction of the switch. In addition, do not use gloves which have grease on them.
Check for continuity between the terminals of the switch.
 
Check conditionTerminal connector of testerNormal condition
At free position1 - 2 (for stoplight switch)Continuity exists
(2 Ω or less)
3 - 4 (for brake monitoring switch)No continuity
Press the plunger from the edge of the outer case by the dimension shown in the figure.1 - 2 (for stoplight switch)No continuity
3 - 4 (for brake monitoring switch)Continuity exists
(2 Ω or less)