DTC P2764: Malfunction of the Lockup Solenoid Valve (short to ground)
 
 
 
 
DIAGNOSTIC FUNCTION
If a predetermined current does not flow into the lock-up solenoid valve (short to ground), the TCM will determine the system is defective.
 
 
DESCRIPTIONS OF MONITOR METHODS
Owing to short to ground, more current than predetermined flows into the lockup solenoid valve drive circuit.
 
 
MONITOR EXECUTION
  • Continuous
 
 
MONITOR EXECUTION CONDITIONS (OTHER MONITOR AND SENSOR)
Other Monitor (There is no temporary DTC stored in memory for the item monitored below)
  • Not applicable
Sensor (The sensor below is determined to be normal)
  • Not applicable
 
 
LOGIC FLOW CHARTS (Monitor Sequence)
 
 
DTC SET CONDITIONS
Check Conditions
  • Voltage of battery: 10 volts or more.
  • Voltage of battery: 16.5 volts or less.
Judgment Criteria
  • A current of at least 1.78 A flows into the lockup solenoid valve drive circuit for 0.5 seconds.
 
 
OBD-II DRIVE CYCLE PATTERN
The vehicle is driven for at least 5 seconds at the speed of 20 km/h (12.4 mph) or more.
 
 
PROBABLE CAUSES
  • Malfunction of the valve body assembly (Faulty lockup solenoid valve)
  • Damaged wiring harness and connectors
  • Malfunction of TCM
 
 
DIAGNOSIS
STEP 1. Check the following connector
  • CVT assembly connector
  • TCM connector
Check the terminals for a contact status problem and internal short circuit.
Is the check result normal?
Go to Step 2.
Repair the defective connector(s).
 
STEP 2. Check for short to ground in LULS line between the CVT assembly connector and the TCM connector
Is the check result normal?
Go to Step 3.
Repair the wiring harness.
 
STEP 3. Lockup solenoid valve check
Refer to .
Is the check result normal?
Go to Step 4.
Replace the valve body assembly.
 
STEP 4. Symptom recheck after erasing diagnostic trouble code
Is the diagnostic trouble code stored?
Replace the TCM.
Intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunctions .).