STEP 6. Measure the output wave pattern of the output speed sensor at TCM connector (OUTS terminal).
(1) Connect the output speed sensor connector and TCM connector.
(2) Selector lever position: D range.
(3) Drive at a constant speed of approx. 20 km/h.
(4) Connect an oscilloscope, and measure the voltage between TCM connector OUTS terminal and body ground.OK: A wave pattern such as the one shown on (Check Procedure Using an Oscilloscope) should be output, and the maximum value should be 11 V or more and the minimum value should be 1 V or less. There should be no noise in the output wave pattern. Is the check result normal?
Go to Step 7. Replace the output speed sensor.