[Previous][Next]
REMOVAL AND INSTALLATION
 
 
caution
  • When removing or installing the mass airflow sensor, be careful not to apply impact to the sensor.
  • Do not reuse the mass airflow sensor that has been dropped.
Air cleaner element removal
8.Air cleaner element
Removal steps
1.Breather hose connection
2.Breather hose connection <CVT>
3.Air cleaner assembly
4.Air intake hose
>>A<<5.Mass airflow sensor
6.O-ring
7.Air cleaner cover
8.Air cleaner element
9.Air duct
10.Air cleaner body assembly
11.Air cleaner bracket
 
 
INSTALLATION SERVICE POINT
 
 
>>A<< MASS AIRFLOW SENSOR INSTALLATION
1. Install the mass airflow sensor to the air cleaner cover with care not to damage the O-ring.
2.
cautionDo not over-tighten. If the mounting screw is over-tightened, the air cleaner cover can be damaged.
Tighten the mounting screws to the specified torque.
Tightening torque: 1.5 ± 0.3 N·m (13 ± 2 in-lb)