[Previous][Next]
DTC Description
 
 
DTC DETECTION LOGIC
DTC No. M.U.T.-III SE screen terms
(Trouble diagnosis content)
DTC detection condition
U2165–87CAN comm err (sonar)
[Controller area network communication error (sonar)]
Diagnosis conditionWhen electric motor switch is ON
Signal (terminal)CAN communication signal
ThresholdCommunication error
Diagnosis delay time2 seconds or more
 
 
POSSIBLE CAUSE
CAN communication system (sonar)
 
 
FAIL-SAFE
The system using the CAN communication signal from control unit which cannot communicate does not function.
 
 
CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
With M.U.T.-III SE
  1. Turn the electric motor switch ON.
  2. Turn the electric motor switch OFF and wait at least 4 minutes or more.
  3. Turn the electric motor switch ON and wait at least 1 minute or more.
  4. Select “Diagnostic Trouble Code” mode of “MULTI AV” using M.U.T.-III SE.
  5. Check DTC.
Is DTC “U2165–87” detected?
-1To check malfunction symptom before repair: Refer to Intermittent IncidentIntermittent Incident.
-2Confirmation after repair: INSPECTION END