[Previous][Next]
Diagnosis Procedure
1.CHECK AROUND VIEW MONITOR CONTROL UNIT POWER SUPPLY CIRCUIT
Check around view monitor control unit power supply circuit. Refer to Diagnosis Procedure.
Is the inspection result normal?
.
Repair or replace malfunctioning parts.
 
2.CHECK LVDS CABLE 1
  1. Turn the electric motor switch OFF.
  2. Check the connection status of the LVDS cable connector. (around view monitor control unit side, wire to wire, and each camera side)
Is inspection result normal?
.
Connect the LVDS cable connector correctly.
 
3.CHECK LVDS CABLE 2
  1. Turn the electric motor switch OFF.
  2. Disconnect around view monitor control unit connector and each camera connector.
  3. Check continuity between around view monitor control unit harness connector and each camera harness connector.
    Around view monitor control unitEach cameraContinuity
    ConnectorTerminalsConnectorTerminals
    B8139Front cameraB841Existed
    33Side camera LHD511
    35Side camera RHD1511
    37Rear cameraD5201
Is inspection result normal?
Replace around view monitor control unit. Refer to Removal and Installation.
Replace defective LVDS cable.