[Previous][Next]
Diagnosis Procedure
1.CHECK REAR VIEW CAMERA POWER SUPPLY CIRCUITS FOR SHORT TO GROUND
With M.U.T.-III SE
  1. Turn electric motor switch OFF.
  2. Disconnect AV control unit harness connector and rear view camera harness connector.
  3. Check the continuity between rear view camera harness connector and ground.
    Rear view cameraGroundContinuity
    ConnectorTerminal
    M10228Not existed
Is the inspection result normal?
Replace rear view camera. Refer to Removal and Installation.
Repair or replace harness or connectors.