Diagnosis Procedure
1.
CHECK FRONT SONAR SENSOR SIGNAL RH INNER CIRCUIT (OPEN)
Turn electric motor switch OFF.
Disconnect sonar control unit connector and front sonar sensor RH inner connector.
Check continuity between sonar control unit harness connector and front sonar sensor RH inner connector
Sonar control unit
Front sonar sensor RH inner
Continuity
Connector
Terminal
Connector
Terminal
B20
1
E306
2
Existed
Is the inspection result normal?
.
Repair the harness or connector.
2.
CHECK FRONT SONAR SENSOR RH INNER GROUND CIRCUIT
Check continuity between sonar control unit harness connector and front sonar sensor RH inner harness connector.
Sonar control unit
Front sonar sensor RH inner
Continuity
Connector
Terminal
Connector
Terminal
B20
13
E306
3
Existed
Is the inspection result normal?
.
Repair the harness or connector.
3.
CHECK FRONT SONAR SENSOR SIGNAL RH INNER
Connect sonar control unit connector and front sonar sensor RH inner connector.
Turn electric motor switch ON.
Check the signal between sonar control unit terminals as per the following condition.
+
−
Condition
Voltage
Sonar control unit
Connector
Terminal
Connector
Terminal
B20
1
B20
13
Shift position is in R position.
When the sensor is detecting an obstacle
Is the inspection result normal?
Replace the sonar control unit. Refer to
Removal and Installation
.
Replace the front sonar sensor RH inner. Refer to
Description
.