[Previous][Next]
Diagnosis Procedure
1.CHECK FRONT SONAR SENSOR SIGNAL RH INNER CIRCUIT (OPEN)
  1. Turn electric motor switch OFF.
  2. Disconnect sonar control unit connector and front sonar sensor RH inner connector.
  3. Check continuity between sonar control unit harness connector and front sonar sensor RH inner connector
    Sonar control unitFront sonar sensor RH innerContinuity
    ConnectorTerminalConnectorTerminal
    B201E3062Existed
Is the inspection result normal?
.
Repair the harness or connector.
 
2.CHECK FRONT SONAR SENSOR RH INNER GROUND CIRCUIT
Check continuity between sonar control unit harness connector and front sonar sensor RH inner harness connector.
Sonar control unitFront sonar sensor RH innerContinuity
ConnectorTerminalConnectorTerminal
B2013E3063Existed
Is the inspection result normal?
.
Repair the harness or connector.
 
3.CHECK FRONT SONAR SENSOR SIGNAL RH INNER
  1. Connect sonar control unit connector and front sonar sensor RH inner connector.
  2. Turn electric motor switch ON.
  3. Check the signal between sonar control unit terminals as per the following condition.
    +ConditionVoltage
    Sonar control unit
    ConnectorTerminalConnectorTerminal
    B201B2013
    • Shift position is in R position.
    • When the sensor is detecting an obstacle
Is the inspection result normal?
Replace the sonar control unit. Refer to Removal and Installation.
Replace the front sonar sensor RH inner. Refer to Description.