2.CHECK BATTERY POWER SUPPLY VOLTAGE
- Disconnect IPDM E/R connector.
- Check voltage between IPDM E/R harness connector and the ground.
+ | - | Voltage |
IPDM E/R |
Connector | Terminal |
E118 | 2 | Ground | 6 – 16 V |
F41 | 81 |
Is the inspection result normal?
Repair the battery power supply circuit.