Component Inspection
1.
CHECK IGNITION RELAY-2
Electric motor switch to OFF.
Remove ignition relay-2.
Check continuity between ignition relay-2 terminals.
Ignition relay-2
Condition
Continuity
Terminal
12 V direct current supply between terminals
and
.
Existed
No current supply
Not existed
Is the inspection result normal?
INSPECTION END