[Previous][Next]
FUEL FILLER LID CHECK
 
 
FUEL FILLER LID RELEASE ACTUATOR CHECK
 
Fuel filler lid release actuator rod12V battery connected terminal No.Normal condition
Unlocked (Rod was pulled in)1(+) - 2(-)Rod protrudes
 
 
 
FUEL FILLER LID OPENER SWITCH CHECK
 
Switch positionTerminal No.Normal value
ON (Operated)5 - 7Continuity exists (2 Ω or less)
OFF5 - 7No continuity
 
Battery voltage12V battery connected terminal No.Normal condition
When live1(-) - 4(+)Illuminated
When not liveNot connectedNot illuminated
 
 
 
FUEL FILLER LID LOCK SENSOR INSPECTION
 
Rod positionTerminal No.Normal condition
ON3 - 4Conducting (2 Ω or less)
OFF3 - 4Not conducting