FUEL FILLER LID CHECK
FUEL FILLER LID RELEASE ACTUATOR CHECK
Fuel filler lid release actuator rod
12V battery connected terminal No.
Normal condition
Unlocked (Rod was pulled in)
1(+) - 2(-)
Rod protrudes
FUEL FILLER LID OPENER SWITCH CHECK
Switch position
Terminal No.
Normal value
ON (Operated)
5 - 7
Continuity exists (2 Ω or less)
OFF
5 - 7
No continuity
Battery voltage
12V battery connected terminal No.
Normal condition
When live
1(-) - 4(+)
Illuminated
When not live
Not connected
Not illuminated
FUEL FILLER LID LOCK SENSOR INSPECTION
Rod position
Terminal No.
Normal condition
ON
3 - 4
Conducting (2 Ω or less)
OFF
3 - 4
Not conducting