When keyless operation key unit detects that keyless operation key system malfunctions or that the engine cannot be started, meter display signal is transmitted by keyless operation key unit to combination meter via CAN communication.
When combination meter receives meter display signal, keyless operation key system malfunction displays.
WARNING/INDICATOR OPERATING CONDITION
When any of the following conditions are satisfied.
The engine cannot be started.
Keyless operation key system malfunction is detected.
WARNING/INDICATOR CANCEL CONDITION
When any of the following conditions are satisfied.
Keyless operation key system malfunction or engine non-start status is resolved.
Electric motor switch is turned to OFF, and 15 seconds are passed.