A/C COMPRESSOR OUTLET TEMPERATURE SENSOR INSPECTION
1. Using the M.U.T.-III SE, read “Discharge Refrigerant Temp Sensor Value” in the PHEV A/C amplifier, then write down the value.
2. Disconnect the A/C compressor outlet temperature sensor connector.
3. Measure the resistance value between the terminals of the A/C compressor outlet temperature sensor side connector.
Estimate the normal resistance value from the sensor value read in step 1 and the sensor value in the table below.
If it is out of standard value, replace the A/C compressor outlet temperature sensor.
TerminalStandard value
12At 0°C (32°F) : 271.5 – 370.4 kΩ
At 10°C (50°F) : 166.6 – 222.7 kΩ
At 20°C (68°F) : 105.0 – 137.7 kΩ
At 30°C (86°F) : 67.8 – 87.5 kΩ
At 40°C (104°F) : 44.9 – 57.0 kΩ
At 50°C (122°F) : 30.4 – 38.0 kΩ
At 60°C (140°F) : 21.0 – 25.8 kΩ
At 70°C (158°F) : 14.8 – 17.9 kΩ
At 80°C (176°F) : 10.6 – 12.7 kΩ
At 90°C (194°F) : 7.7 – 9.1 kΩ
At 100°C (212°F) : 5.7 – 6.7 kΩ
At 110°C (230°F) : 4.3 – 5.0 kΩ
At 120°C (248°F) : 3.3 – 3.7 kΩ
At 130°C (266°F) : 2.5 – 2.8 kΩ