EVAPORATOR OUTLET TEMPERATURE SENSOR INSPECTION
1. Using the M.U.T.-III SE, read “Evaporator Outlet Refrigerant Temp Sensor Value” in the PHEV A/C amplifier, then write down the value.
2. Disconnect the evaporator outlet temperature sensor connector.
3. Measure the resistance value between the terminals of the evaporator outlet temperature sensor side connector.
Estimate the normal resistance value from the sensor value read in step 1 and the sensor value in the table below.
If it is out of standard value, replace the evaporator outlet temperature sensor.
TerminalStandard value
12At -20°C (-4°F) : 15.11 – 15.70 kΩ
At -10°C (14°F) : 9.35 – 9.58 kΩ
At 0°C (32°F) : 5.94 – 6.06 kΩ
At 10°C (50°F) : 3.87 – 3.96 kΩ
At 20°C (68°F) : 2.57 – 2.66 kΩ
At 30°C (86°F) : 1.75 – 1.83 kΩ
At 40°C (104°F) : 1.22 – 1.29 kΩ
At 50°C (122°F) : 0.87 – 0.92 kΩ
At 60°C (140°F) : 0.63 – 0.67 kΩ
At 70°C (158°F) : 0.46 – 0.50 kΩ
At 80°C (176°F) : 0.35 – 0.37 kΩ