HIGH PRESSURE MAGNETIC A/C VALVE INSPECTION
1. Disconnect the high pressure magnetic A/C valve connector.
2. Measure the resistance value between the terminals of the high pressure magnetic A/C valve side connector.
If it is out of standard value, replace the high pressure magnetic A/C valve.
Standard value: 12.2 – 13.7 Ω (At 20°C (68°F))
3. Confirm that the operation sound can be heard when battery voltage is applied to the terminal on one side of the high pressure magnetic A/C valve side connector, and the other connector is connected to the body ground.
If the operation sound cannot be heard, replace the high pressure magnetic A/C valve.