Reference value
 
 
VALUES ON THE M.U.T.-III SE
noteThe following table includes information (items) inapplicable to this vehicle. For information (items) applicable to this vehicle, refer to M.U.T.-III SE display items.
Item No.M.U.T.-III SE screen termsConditionReference valve in normal operation
13iB Temperature Therm Ch1Always120°C (248°F) or less
14iB Temperature Therm Ch2Always120°C (248°F) or less
15iB Power Supply BatteryAlways10–16V
16iB Power Supply ECUWhen the power supply mode of the electric motor switch is ON10–16V
19eDLC VoltageAlways10–16V
28Vehicle speedVehicle is stopped
Running
Vehicle is stopped: 0km/h
Running: The speedometer display and the M.U.T.-III SE display almost agree with each other.
31Pressure Run OutBrake pedal is gradually depressed0 – 25MPa