[Previous][Next]
Diagnosis Procedure
1.CHECK CONNECTOR
  1. Disconnect 12V battery negative terminal.
  2. Check the ABS actuator and electric unit (control unit) harness connector for disconnection or looseness.
Is the inspection result normal?
.
Repair / replace harness or connector, securely lock the connector. .
 
2.PERFORM DIAGNOSTIC TROUBLE CODE
With M.U.T.-III SE
  1. Connect 12V battery negative terminal.
  2. Electric motor switch ON.
    noteWait at least 10 seconds after electric motor switch ON.
  3. Perform Diagnostic Trouble Code for “ABS".
Is DTC “C104F-04" detected?
.
INSPECTION END
 
3.CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY AND GROUND CIRCUIT
Check the ABS actuator and electric unit (control unit) power supply and ground circuit. Refer to Diagnosis Procedure.
Is the inspection result normal?
.
Repair / replace harness, connector, terminal, fuse, or fusible link.
 
4.CHECK TERMINAL
  1. Disconnect 12V battery negative terminal.
  2. Check the ABS actuator and electric unit (control unit) terminals for damage or loose connection with harness connector.
Is the inspection result normal?
Replace the ABS actuator and electric unit (control unit). Refer to Removal and Installation.
Repair / replace harness, connector, or terminal.