caution | The insulation resistance check must be completed within 10 seconds. (Since DC 1,000 V is applied while checking, parts may be damaged if the check continues for 10 seconds or more.) |
Required Special Tools:
- MB991223: Wiring harness set
- MB992006: Extra fine probe
1. Set the range of the electric insulation tester (Special tool: MB992355) to 1000 V.
2. Measure the insulation resistance between the junction box high voltage circuit (P1, P2, N1, N2) and junction box (body ground).Standard value: 10 MΩ or more
3. If the resistance value is not the standard value, replace the junction box.