[Previous][Next]
OBD-II DRIVE CYCLE
 
 
All kinds of diagnostic trouble codes (DTCs) can be monitored by carrying out a short drive according to the following 3 drive cycle patterns. In other words, doing such a drive regenerates any kind of trouble which involves illuminating the Malfunction Indicator light (SERVICE ENGINE SOON or Check Engine light) and verifies that the trouble has been eliminated [The Malfunction Indicator light (SERVICE ENGINE SOON or Check Engine light) is no longer illuminated].
cautionTwo technicians should always be in the vehicle when carrying out a test.
noteCheck that the diagnostic trouble code (DTC) is not set before driving the OBD-II drive cycle. Erase the DTC if it has been set.
 
 
DRIVE CYCLE PATTERN LIST
MONITOR ITEMDTCPATTERN
AC input over currentP0D2A-003
DC Output current control failureP0D22-00
Input current sensorNo chargeP0D39-001
Circuit-lowP0D3A-00
Circuit-highP0D3B-00
Input voltage sensorFailureP0D3E-00
Circuit-lowP0D3F-00
Circuit-highP0D40-00
Output voltage sensorCircuit-lowP0D4E-00
Circuit-highP0D4F-00
Output current sensorNo chargeP0D52-00
Circuit-lowP0D53-00
Circuit-highP0D54-00
DC output  over voltageP0D85-003
ROM check error(CRC error)/RAM check error (Read/Write)P0E5E-001
PFC voltage control failureP1C52-49, P1C53-49, P1C54-493
Inverter over currentP1C55-493
AD converter failureP1C5A-461
PFC output voltage sensorCircuit-highP1C5C-123
Circuit-lowP1C5D-11
Internal temperature sensor failureP1C5E-962
PFC temperature sensorCircuit-highP1C60-121
Circuit-lowP1C61-11
Boosting part temperature sensorCircuit-highP1C62-121
Circuit-lowP1C63-11
Start request signal  failureP1C64-293
Low output voltage failureP1C6E-163
CAN failureU1D40-87, U1D41-87, U1D42-871
 
 
PATTERN 1
Test procedure
  1. Change the power supply mode of the electric motor switch to ON.
  2. Wait for 10 seconds or more.
  3. Check that the DTC is not set.
 
 
PATTERN 2
Test procedure
  1. Change the power supply mode of the electric motor switch to ON.
  2. Wait for 5 minutes or more.
  3. Check that the DTC is not set.
 
 
PATTERN 3
Test procedure
  1. Change the power supply mode of the electric motor switch to ON.
  2. Change the power supply mode of the electric motor switch to OFF.
  3. Connect the normal charging cable and start normal charging.
  4. Wait for 1 minute or more.
  5. Press the charge connector unlock switch, and disconnect the normal charging cable to end charging.
  6. Check that the DTC is not set.