INITIALISATION PROCEDURE
1. After the power supply mode of the electric motor switch is OFF, connect the scan tool (M.U.T.-III SE) to the data link connector.
2. Operate the electric motor switch without depressing the brake pedal and turn the power supply mode of electric motor switch to ON.
3. Select "ENGINE" from System select Screen of the scan tool (M.U.T.-III SE).
4. Select "Special Function" from ENGINE Screen.
5. Select "Learned value reset" from Special Function Screen.