3.CHECK HARNESS BETWEEN SPIRAL CABLE AND ECM
- Disconnect the ECM connector.
- Check for continuity between the spiral cable harness connector and ECM harness connector.
Spiral cable | ECM | Continuity |
Connector | Terminal | Connector | Terminal |
M30 | 8 | E16 | 142 | Existed |
1 | 143 |
- Check for continuity between spiral cable harness connector and ground.
Spiral cable | Ground | Continuity |
Connector | Terminal |
M30 | 8 | Not existed |
1 |
Is the inspection result normal?
Repair the harnesses or connectors.