Description
Vehicle specification needs to be written with M.U.T.-III SE because it is not written after replacing the multi-around monitor control unit.
The configuration requires network connection. M.U.T.-III SE connects to network and then it downloads the configuration data from the server. Then M.U.T.-III SE writes the vehicle specification to the multi-around monitor control unit.
note | For details the network connection and operation, refer to “M.U.T.-III SE Operation Manual”. The configuration no need to “save” configuration data from the multi-around monitor control unit. The configuration data is always generated freshly at the server and then downloaded to the M.U.T.-III SE. |
caution | - Complete the procedure of “Configuration” in order.
- If incorrect “Configuration”, incidents might occur.
|