[Previous][Next]
Diagnosis Procedure
1.CHECK FRONT SONAR SENSOR SIGNAL RH OUTER CIRCUIT (SHORT)
  1. Turn ignition switch OFF.
  2. Disconnect sonar control unit connector and front sonar sensor RH outer connector.
  3. Check continuity between sonar control unit harness connector and ground.
Sonar control unitGroundContinuity
ConnectorTerminal
B204Not existed
Is the inspection result normal?
Replace the Front sonar sensor RH outer. Refer to Removal and Installation.
Repair the harness or connector.