Diagnosis Procedure
1.
CHECK FRONT SONAR SENSOR SIGNAL RH INNER CIRCUIT (OPEN)
Turn ignition switch OFF.
Disconnect sonar control unit connector and front sonar sensor RH inner connector.
Check continuity between sonar control unit harness connector and front sonar sensor RH inner connector.
Sonar control unit
Front sonar sensor RH inner
Continuity
Connector
Terminal
Connector
Terminal
B20
1
E306
2
Existed
Is the inspection result normal?
.
Repair the harness or connector.
2.
CHECK FRONT SONAR SENSOR RH INNER GROUND CIRCUIT
Check continuity between sonar control unit harness connector and front sonar sensor RH inner harness connector.
Sonar control unit
Front sonar sensor RH inner
Continuity
Connector
Terminal
Connector
Terminal
B20
13
E306
3
Existed
Is the inspection result normal?
Replace the front sonar sensor RH inner. Refer to
Removal and Installation
.
Repair the harness or connector.