[Previous][Next]
DTC Description
noteThe ignition relay does not turn ON for 3 seconds after emergency OFF even if the push-button ignition switch is pressed.
 
 
DTC DETECTION LOGIC
DTC No.M.U.T.-III SE screen items
(Trouble diagnosis content)
DTC detection condition
B20DD-73IGN RELAY ON CIRC
(Ignition relay on circuit)
[ACTUATOR STUCK CLOSED]Diagnosis conditionWhen ignition switch is OFF
Signal (terminal)CPU monitors the status at the contact and excitation coil circuits of the ignition relay inside it
ThresholdThe ignition relay ON is detected
Diagnosis delay time1 second or more
 
 
POSSIBLE CAUSE
IPDM E/R
 
 
FAIL-SAFE
 
 
DTC CONFIRMATION PROCEDURE
1.PERFORM DTC CONFIRMATION PROCEDURE
With M.U.T.-III SE
  1. Ignition switch ON.
  2. Ignition switch OFF and wait for 1 second or more.
  3. Ignition switch ON.
  4. Check “Self Diagnostic Result” of “IPDM E/R” using M.U.T.-III SE.
Is DTC detected?
-1 To check malfunction symptom before repair: Refer to Intermittent IncidentIntermittent Incident.
-2 Confirmation after repair: INSPECTION END