Component Inspection
1.
CHECK IGNITION RELAY-3
Ignition switch OFF.
Remove ignition relay-3.
Check continuity between ignition relay-3 terminals.
Ignition relay-3
Condition
Continuity
Terminal
3
4
12 V direct current supply between terminals 1 and 2.
Existed
No current supply
Not existed
Is the inspection result normal?
INSPECTION END
Replace ignition relay-3.