Component Inspection
1.
CHECK IGNITION RELAY-1
Ignition switch OFF.
Remove ignition relay-1.
Check continuity between ignition relay-1 terminals.
Ignition relay-1
Condition
Continuity
Terminal
12 V direct current supply between terminals
and
.
Existed
No current supply
Not existed
Is the inspection result normal?
INSPECTION END
Replace ignition relay-1.