Work Procedure
 
 
DESCRIPTION
When replacing 8CH CAN gateway, the following procedure must be performed.
 
 
WORK PROCEDURE
1.REPLACE 8CH CAN GATEWAY
Replace 8CH CAN gateway. Refer to Removal and Installation.
: .
 
2.PERFORM 8CH CAN GATEWAY PROGRAMMING
M.U.T.-III SE Configuration
Perform the 8CH CAN gateway programming. Refer to “M.U.T.-III SE Operation Manual”.
: .
 
3.CHECK ALL ECU SELF-DIAGNOSIS RESULTS
  1. Erase all ECU self-diagnosis results using M.U.T.-III SE.
  2. Turn the ignition switch OFF.
  3. Turn the ignition switch ON and wait for 2 seconds or more.
  4. Check that all ECU self-diagnosis results have no DTC (e.g. U1000 and U1001) of CAN communication.
: WORK END