8CH CAN gateway harness connector | ADAS control unit 2 harness connector | Continuity | ||
Connector No. | Terminal No. | Connector No. | Terminal No. | |
M29 | 37 | B4 | 28 | Existed |
38 | 29 | Existed |
8CH CAN gateway harness connector | Continuity | ||
Connector No. | Terminal No. | ||
M29 | 37 | 38 | Not existed |
8CH CAN gateway harness connector | Ground | Continuity | |
Connector No. | Terminal No. | ||
M29 | 37 | Not existed | |
38 | Not existed |
8CH CAN gateway | Resistance (Ω) | |
Terminal No. | ||
37 | 38 | Approx. 108 – 132 |
ADAS control unit 2 | Resistance (Ω) | |
Terminal No. | ||
28 | 29 | Approx. 108 – 132 |
note | 8CH CAN gateway and ADAS control unit 2 have a termination circuits. Check other units first. |
note | Although unit-related error symptoms occur, do not confuse them with other symptoms. |