BCM harness connector | IPDM E/R harness connector | Continuity | ||
Connector No. | Terminal No. | Connector No. | Terminal No. | |
M18 | 26 | E120 | 24 | Existed |
27 | 22 | Existed |
BCM | Continuity | ||
Connector No. | Terminal No. | ||
M18 | 26 | 27 | Not existed |
BCM | Ground | Continuity | |
Connector No. | Terminal No. | ||
M18 | 26 | Not existed | |
27 | Not existed |
BCM | Resistance (Ω) | |
Terminal No. | ||
26 | 27 | Approx. 108 – 132 |
IPDM E/R | Resistance (Ω) | |
Terminal No. | ||
24 | 22 | Approx. 108 – 132 |
note | BCM and IPDM E/R have a termination circuit. Check other units first. |
note | Although unit-related error symptoms occur, do not confuse them with other symptoms. |