[Previous][Next]
Diagnosis Procedure
1.CHECK FUSE
  1. Ignition switch OFF, and then wait for 3 minutes with driver door open.
    note
    • Even after ignition switch is OFF, power is supplied to accessories for a certain amount of timer by the AUTO ACC function.
    • When vehicle is operate while on standby, power may be supplied to accessories.
  2. Check that the following fuse is not blown (open).
    Fuse No.Current rating
    5220 A
Is the fuse blown (open)?
Repair the blown (open) fuse after repairing the affected circuit if a fuse is blown (open).
.
 
2.CHECK FRONT POWER WINDOW MOTOR (DRIVER SIDE) POWER SUPPLY
  1. Disconnect front power window motor (driver side) connector.
  2. Ignition switch ON.
  3. Check voltage between front power window motor (driver side) harness connector and ground.
(+)(–)Voltage
Front power window motor (driver side)
ConnectorTerminal
D104Ground10 - 16 V
Is the inspection result normal?
.
Repair or replace harness.
 
3.CHECK FRONT POWER WINDOW MOTOR (DRIVER SIDE) GROUND CIRCUIT
  1. Ignition switch OFF.
  2. Check continuity between front power window motor (driver side) harness connector and ground.
Front power window motor (driver side)Continuity
ConnectorTerminal
D103GroundExisted
Is the inspection result normal?
INSPECTION END