[Previous][Next]
Component Inspection
1.CHECK STARTER CUT RELAY
  1. Ignition switch OFF.
  2. Disconnect starter cut relay.
  3. Check continuity between starter cut relay terminals.
    Starter cut relayConditionContinuity
    Terminal
    6712 V direct current supply between terminals 8 and 9Existed
    No current supplyNot existed
Is the inspection result normal?
INSPECTION END
Replace starter cut relay.