Mode Door Motor
 
 
COMPONENT FUNCTION WITHIN SYSTEM
Mode door motor consists of motor that drives door, PBR (Potentio Balance Register) that detects door position and LCU (Local Control Unit) that perform multiplex communication control (LIN) with A/C amp.
 
 
INDIVIDUAL COMPONENT FUNCTION
Rotation of motor is transmitted to each mode door. Air outlet is switched.
 
 
COMPONENT OPERATION
  • LCU (Local Control Unit) is built into mode door motor. And detects door position by PBR (Potentio Balance Resistor).
  • A/C amp. communicates with each LCU via communication line. And receives each mode door position feedback signal from LCU.
  • LCU transmits the signal of door movement completion to A/C amp., when the door movement is completed.
 
 
COMPONENT PARTS LOCATION